AutoCAD 2010 – Turning off InfoCenter

I generally avoid the still-awful Autodesk discussion groups these days, but I do hop in from time to time in the vain hope of seeing some improvement. In doing so, I occasionally pick up a gem, and that happened today. I think this one deserves a wider audience, so here it is.

In AutoCAD 2010, you can disable the InfoCenter toolbar by opening the
registry, and going to the following key:

HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R18.0\ACAD-8001:409\InfoCenter

In that key there’s a value with the name “InfoCenterOn”.

Changing that value from 1 to 0 will disable the InfoCenter toolbar.

Source: Tony Tanzillo in this thread. Note that the “ACAD-8001” part will be different if you use a vertical variant of AutoCAD.

Why would you want to do this? To improve startup times and reduce annoyance. Autodesk should have provided a better mechanism for doing this. The absence of convenient, designed-in off switches for new features is something I’ve complained about on many occasions over the years. Autodesk’s response has been patchy.

Edit: I just noticed Owen Wengerd has posted about this, including a LISP routine to simplify the process of turning it on and off.

Has AutoCAD 2009 eaten your registry lately?

I’ve had a one-off report from a user of AutoCAD 2009 (actually, it was MDT as part of the Inventor suite pretending to be AutoCAD 2009, which isn’t exactly the same thing) and I’d like to know if anyone else has seen the same thing. His AutoCAD self-destructed and a little investigation showed that the section of the Registry that contains all the settings for that particular release had vanished without trace. This happened again later, but this time he had a backup of the Registry section handy and was able to avoid a second reinstall.  No Registry cleaners were involved.