AutoCAD 2010 – Turning off InfoCenter

I generally avoid the still-awful Autodesk discussion groups these days, but I do hop in from time to time in the vain hope of seeing some improvement. In doing so, I occasionally pick up a gem, and that happened today. I think this one deserves a wider audience, so here it is.

In AutoCAD 2010, you can disable the InfoCenter toolbar by opening the
registry, and going to the following key:

HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R18.0\ACAD-8001:409\InfoCenter

In that key there’s a value with the name “InfoCenterOn”.

Changing that value from 1 to 0 will disable the InfoCenter toolbar.

Source: Tony Tanzillo in this thread. Note that the “ACAD-8001” part will be different if you use a vertical variant of AutoCAD.

Why would you want to do this? To improve startup times and reduce annoyance. Autodesk should have provided a better mechanism for doing this. The absence of convenient, designed-in off switches for new features is something I’ve complained about on many occasions over the years. Autodesk’s response has been patchy.

Edit: I just noticed Owen Wengerd has posted about this, including a LISP routine to simplify the process of turning it on and off.